Hvac air duct leakage test manual author.
Hvac air duct leakage test manual pdf.
Iapmo uniform mechanical code duct leakage tests.
Hvac air duct leakage test manual and table 1 1 on page 1 11 in the 2005 smacna hvac duct construction standards.
The hvac air duct leakage test manual has also been incorporated by reference and is required by law in title 19 new york.
Leakage class can be calculated using equation 3 but needs to be specified if duct air leakage tests are required.
Th is table is not an allowable leakage specifi cation but is often used as one.
Contains updates to the expected leakage rates for ductwork constructed to the smacna hvac duct construction standards metal flexible duct leakage test procedures recommendations on use of leakage testing types.
Quote fromquote from hvac air duct leakage testhvac air duct leakage test manual smacna.
The hvac air duct leakage test manual provides practical and detailed procedures for conducting leakage tests.
Figure 5 1l from the 2012 smacna hvac air duct leakage test manual shows the allowable leakage as a function of duct leakage classification and static pressure in the duct.
Schedule the pressure classes here by fan system num ber or portion thereof if they are not shown on the drawings.
Sheet metal and air conditioning contractors national association subject.
Duct seal class ducts shall be sealed as specified in the hvac dcs.
Duct pressure classes are to be identified on the contract drawings.
Public domain created date.
Duct leakage class consult the hvac air duct leakage test manual and.
This american national standard ansi smacna 016 2012 covers revised leakage criteria and builds on the proven methods for testing ductwork for air leaks from the first edition.
Mcgill airflow receives many inquiries each year from contractors who are performing leak tests in the fi eld wanting to know how to use this table to.
Prior to smacna hvac air duct leakage test manual 1985 two id i lidentical phases of a research b ildibuilding were bilbuilt by different contractors.
The ahu systems were dual duct.
Potential accuracy of flow measurements should be evaluated.
Phase 1 by contractor a required.
Issues of sealing duct to a leakage class and seal class case 1.
Ductwork that is designed to operate at static pressures in excess of 3 inches water column 0 75 kpa and all ductwork located outdoors shall be leak tested according to the ansi smacna hvac air duct leakage test manual.
Apparent differences of about ten percent between fan delivery and sum of airflow measurements at terminals do not necessarily mean poor sealing and excess leakage.